Underfloor Heating Manifold Parts: Full Component List

An underfloor heating manifold is not one part — it is a set of roughly a dozen components, and a quotation that misses two of them arrives on site incomplete. This guide lists every part on and around the manifold, gives the quantity rule for each, and turns the list into a purchase order you can check line by line.

i. Certified manufacturer · Manufacturing since 1993 ii. ISO 9001 · 14001 · SGS · CE iii. a complete product range, one source

Most incomplete underfloor heating deliveries are not caused by a missing manifold. They are caused by a missing end cap, bracket, air vent or adaptor — a small part that stops a whole floor from being commissioned. An underfloor heating manifold is sold as one line on a proforma, but it functions as an assembly of ten to fifteen distinct components, several of which most suppliers quote separately. This article lists every part, states how many of each you need as a function of port count, and separates what normally ships in the box from what you have to add to the order yourself.

It is written for the person building the purchase order rather than the person holding the spanner: importers pricing a first container, distributors setting up a stock list, and contractors checking a quotation against a floor plan. For the installation sequence instead — mounting, pressure testing, balancing and wiring — see the companion guide on how to install an underfloor heating manifold. Here we stay on the parts.

I. What Counts as “the Manifold” — and What Does Not

The manifold proper is two horizontal bars mounted one above the other, normally machined from brass. The upper bar is the flow bar: it takes heated water from the heat source out to each floor loop. The lower bar is the return bar: it collects the cooled water coming back. Every loop occupies one outlet on each bar, which is why a manifold is described by its port count — a 6-port manifold serves six heating circuits, using six outlets on the flow bar and six on the return bar.

Ports are not a size. A port is a heating loop — count the circuits on the floor plan and the manifold specifies itself.

Around those two bars sits everything else: the devices that measure flow, the devices that open and close each circuit, the valves that isolate the assembly, the fittings that connect the pipe, and the brackets that hold it on a wall. Some are pre-assembled onto the bars at the factory, some are supplied loose in the same carton, and some are separate order lines entirely — and the boundary moves from supplier to supplier, which is why quotations are hard to compare. Do not assume: read the list below against whatever specification you have been sent, and mark each row as included, extra, or missing.

II. Underfloor Heating Manifold Parts — the Full List

The table below is the complete component set for a standard hydronic underfloor heating manifold assembly, with a quantity rule for each part and a note on whether it typically ships with the manifold or is ordered separately. N is the number of loops, which equals the port count.

ComponentFunctionTypical quantityUsually supplied
Flow barDistributes heated water from the heat source out to each loop1 per manifoldWith the manifold
Return barCollects cooled water returning from each loop1 per manifoldWith the manifold
Flow meters (flow gauges)Display and set the flow rate of each circuit — the tool used to balance the systemN (one per loop)With the manifold on flow-meter versions
Actuator valve seatsThe valve on each return outlet that the electrothermal actuator screws ontoN (one per loop)With the manifold
Electrothermal actuatorsOpen or close one loop on demand from the room thermostatN, or one per zone if loops are groupedOrdered separately
Room thermostatsCall for heat per room or zone and drive the actuators1 per controlled zoneOrdered separately
Isolation / ball valvesShut the whole manifold off from supply and return for service2 (one flow, one return)Often a separate order line
End caps / end piecesClose the far end of each bar; carry the vent and drain ports2 (one per bar)With the manifold
Automatic air ventsPurge trapped air from the high point of the assemblyVersion-dependent: commonly 1–2 per manifold. Some end-sets carry a vent on each bar; on others the vent sits on the flow bar only and the return bar end piece carries a drainPart of the end-set — check the end-set, not the bar count
Drain / fill valvesFill, flush and drain the loops during commissioning and serviceVersion-dependent: commonly 1–2 per manifold, often paired with the vents in a combined vent-and-drain end-piece setPart of the end-set — check the end-set, not the bar count
Mounting bracketsFix the assembly to the wall or into a cabinet, level and clear of the floor1 set (2 brackets)With the manifold
Compression / insert adaptorsConnect each PEX loop to a manifold outlet2 × N (supply and return per loop)Ordered separately by pipe size
Temperature gaugesRead flow and return temperature to confirm the floor is in range1–2 per manifoldVersion-dependent
Pump / mixing groupBlends hot source water down to floor temperature and circulates it1 per manifold where requiredOrdered separately
Manifold cabinetRecessed or surface enclosure protecting the assembly1 per manifold, sized to port countOrdered separately
Wiring centreCommon terminal point between thermostats, actuators and the heat source1 per systemOrdered separately

Quantities and inclusions are general industry guidance, not a WARMHAUS-specific specification. What ships in the carton differs by manifold version and by supplier — always confirm the scope of supply against the datasheet and packing list of the manifold you are actually buying, and against the technical data of the pipe and controls you pair with it.

The end-set rows deserve a closer look, because they are the ones most often read as a fixed rule when they are not. It is convenient to say “one vent and one drain per bar”, and on many manifolds that is what arrives. But the arrangement is genuinely version-dependent: some end-sets put an automatic vent on each bar; others put the vent on the flow bar — the natural high point for air to collect — and give the return bar a drain-and-fill cock only; others again supply a single combined vent-plus-drain end piece per bar as one part number. All three are normal. What matters commercially is not which arrangement you prefer but that you count the end-set as one line and read what is in it, rather than assuming a quantity of two and discovering on site that the assembly cannot be vented or cannot be drained.

Two further rows cause most of the shortfalls. The outlets are threaded, so the connection to the floor pipe is made by an adaptor sized to the pipe you are running — two per loop, not one. And manifolds ship with the valve seats but rarely with the actuator heads, because the head has to match the control voltage and the thermostat; both sit in the underfloor heating controls range.

III. How to Turn a Floor Plan Into a Parts Count

The whole bill of materials derives from one number — the loop count — so establishing that number correctly is the entire exercise. Work through it in this order.

i.

Count the circuits, not the rooms

Each heated area needs at least one loop, and a large open-plan area is normally split into two or more circuits so no loop exceeds the maximum length the designer allows. The circuit count on the heating layout — not the room count on the architectural plan — is your N.

ii.

Round the port count up, never down

If the plan gives five loops, specify a six-port manifold. The spare outlet is capped now and used later when a conservatory, garage or extension is added, and it costs far less than a second manifold and a second supply run.

iii.

Split by floor, not by building

A single very large manifold is harder to balance and forces long loop runs back to one point. Standard practice is one manifold per floor or wing, each with its own isolation valves — so a two-storey house is usually two smaller assemblies.

iv.

Count actuators by zone, not always by loop

Where several loops serve one thermostatically controlled area, they can share a zone and switch together. That reduces the actuator and thermostat count below N — but only if the zoning is decided before the order, because the wiring centre is sized for it.

v.

Fix the pipe size before the adaptors

Adaptors are ordered against the outside diameter and wall of the floor pipe. Change the pipe specification afterwards and the whole adaptor line is scrap — the most common reason a manifold shipment cannot be connected on arrival.

vi.

Size the cabinet against the assembled width

The enclosure has to clear the assembled manifold including the flow meters, the actuator heads and any pump group — not the bare bar length. Cabinet sizes step up with port count, so specify it from the final assembly rather than from the manifold model number alone.

Brass underfloor heating manifolds packed in a crate with brackets and end pieces before export
One manifold, one complete parts set — packed as an assembly rather than as loose lines.Manifold packing

IV. The Parts Most Often Missing From a Quotation

A quotation is not a bill of materials. Four components sit outside the headline manifold price often enough to be worth checking every time. Adaptors — a quotation listing a manifold and a pipe coil but no adaptors describes parts that cannot be joined. Isolation valves — frequently assumed to be part of the manifold and frequently not; without them, servicing one manifold means draining the system. The pump or mixing group — required wherever the heat source delivers water hotter than the floor construction allows, which makes it a design decision rather than a default inclusion. The cabinet and wiring centre — both sized from the rest of the assembly, both usually remembered only when the installer arrives.

The practical defence is to quote from the parts table above rather than from a supplier’s product page, and to ask one direct question of every line: is this included, or is this extra? A supplier that answers that line by line is a supplier whose container arrives complete. If you are assembling a first order, request the manifold and controls specification sheets from our technical office and we will mark each component as included or separate against your port count.

V. Why the Parts Should Come From One Manufacturer

Every interface in the list above is a place where two parts have to fit each other: the actuator head onto the valve seat, the adaptor onto the outlet, the thermostat signal into the actuator, the assembly into the cabinet. When those parts come from four suppliers, each interface becomes a tolerance question — and the answer only arrives when the crate is opened on site.

WARMHAUS builds the manifold, the controls and the pipe. We are a manufacturer of PPR, PEX and brass piping systems — not a trading company — and the machining, extrusion and injection-moulding lines are our own. That is why the brass underfloor heating manifold range is dimensioned around the same PEX pipe and electrothermal actuators we produce, and why the same machined body also appears in the wider brass manifold line used for potable water distribution. One drawing set, one internal standard, one packing list. Port counts across the industry commonly run from 2 to 12 loops per manifold as general industry guidance — how to arrive at the right number for a given floor is worked through in the manifold sizing guide; confirm the counts available in any specific range against the current datasheet.

For a distributor that means a shelf answering a whole enquiry instead of half of one — manifold, actuators, thermostats, pipe and adaptors on a single account across the complete product range, with no MOQ, so a first order can be a mixed pallet rather than a container of one item. Manufacturing since 1993, ISO 9001 / ISO 14001 / ISO 45001 certified, EU CE marked and SGS tested, with certification files supplied for tender and customs paperwork. Standard lead time 45 days from order confirmation, planned into production slots. Port counts, dimensions, certificate documents and pricing: available on request.

FAQ Common questions

Manifold Parts — Frequently Asked Questions

For the Sourcing Agent / Importer
A complete assembly is a flow bar and a return bar, flow meters and actuator valve seats (one of each per loop), an end-set carrying the automatic air vent or vents and the drain and fill valves, mounting brackets, and isolation valves on supply and return. How the vents and drains are divided between the two bars is version-dependent, so read the end-set contents rather than assuming one of each per bar. Around it sit the electrothermal actuators, room thermostats, pipe adaptors, an optional pump or mixing group, a cabinet and a wiring centre. The first group normally ships with the manifold; the second is usually ordered separately.
For the Specifier / Consultant
One port per heating loop, counted from the heating layout rather than the room list — large open areas are usually split into two or more circuits. Total the loops for that floor, then round up one size so a spare outlet is available for a later extension. Where a floor needs more circuits than one manifold can carry comfortably, split it into two manifolds with their own isolation valves rather than specifying one very large assembly.
For the New Distributor
Normally no. The manifold carries the valve seat that the actuator screws onto, but the actuator head itself is specified by control voltage and has to match the thermostat, so it is almost always a separate order line — as is the thermostat and the wiring centre. Treat the control layer as its own section of the purchase order and confirm voltage and control type before the order is placed, not after the crate arrives.
For the Installer
Two — one at the flow bar and one at the return bar, because every loop connects at both ends. A six-port manifold therefore needs twelve adaptors, not six. They are sized to the outside diameter and wall of the floor pipe, so fix the pipe specification before ordering them; changing pipe size afterwards makes the whole adaptor line unusable. This is the most common reason a manifold delivery cannot be connected on the day.
For the Sourcing Agent / Importer
Yes. WARMHAUS manufactures the brass manifolds, the electrothermal actuators and thermostats, and the PEX pipe on its own machining, injection-moulding and extrusion lines, so the actuator thread, the outlet dimension and the pipe size are held to one internal standard instead of averaged across suppliers. Manufacturing since 1993, ISO 9001 / ISO 14001 / ISO 45001 certified, EU CE marked and SGS tested, with no MOQ and a standard lead time of 45 days.Port counts, dimensions and certificate documents: available on request.